CBMWM - MISTY INDUSTRIAL CLEANING SOLVENT

  • MSDS: CBMWM
  • Manufacturer: AMREP INC
  • Product Name: MISTY INDUSTRIAL CLEANING SOLVENT
  • National Stock Number: 6850-00N070960
Product Identification

Product ID:MISTY INDUSTRIAL CLEANING SOLVENT
MSDS Date:09/02/1994
FSC:6850
NIIN:00N070960
MSDS Number: CBMWM

Responsible Party
AMREP INC
990 INDUSTRIAL PARK DR
MARIETTA, GA 30062
US

Emergency Phone: 800-255-3924

Info Phone: 404-422-2071

Preparer: DL/KD

Cage: 3V338

Contractor
AMREP INC
MARIETTA, GA 30062-2433 US

Telephone: 404-422-2071

Cage: 3V338

Ingredients

ETHYLENE, TRICHLORO-; (TRICHLOROETHYLENE) (SARA 313)

CAS: 79-01-6

RTECS: KX4550000

OSHA PEL 100 PPM; Z-2

ACGIH TLV: 50 PPM/100 STEL, A5

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


ETHYLENE, TETRACHLORO-; (PERCHLOROETHYLENE) (SARA 313)

CAS: 127-18-4

RTECS: KX3850000

OSHA PEL 100 PPM, Z-2

ACGIH TLV: 25 PPM/100 STEL, A3

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


INCREASE RATE OF SPONTANEOUSLY OCCURRING

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A SIMILAR
EFT IN HUMANS. ADRENOMIMETICS (E.G. EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAIN ING USES IN HUMANS ACUTELY
OR CHRONICALLY EXPOSED TO CHLOROCARBONS . ACUTE:INHAL:EXCESS INHAL
(ETS OF OVEREXP)
Explanation of Carcinogenicity:TRICHLOROETHYLENE:IARC MONOGRAPHS ON
EVALUTION OF CARCIN RISK OF CHEMS TO MAN, VOL 63, PG 75, 1995:GROUP
2A. (SUPDAT)
Effects of Overexposure:HLTH HAZ:OF VAPS CAN BE HARMFUL AND MAY CAUSE
HDCH, DIZZ, ASPHYXIA, ANESTHETIC EFTS & POSS UNCON. EYE:IRRIT.
SKIN:IRRIT DUE TO DEFAT OF SKIN. INGEST:POSS CHEM PNEUM IF
ASPIRATED INTO LUNGS. NAUS. CHRO NIC:MAY CAUSE LIVER ABNORM,
KIDNEY, SPLEEN, LUNG/BRAIN DMG, CARD ABNORM. PERCHLOROETHYLENE HAS
BEEN SHOWN TO (ING 3)
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING EYE, SKIN,
OR UPPER RESPIRATORY CONDITIONS.

First Aid

First Aid:EYE:FLUSH WITH WATER FOR AT LEAST 15 MINUTES. IF IRRITATED,
SEEK MED ATTN. SKIN:WASH WITH SOAP AND WATER. IF IRRITATED, SEEK
MED ATTN. INHAL:REMOVE TO FRESH AIR. RESUSITATE IF NECESSARY. GET
MED ATTN. INGEST:DO NOT INDUCE VOMITING. DRINK TWO LARGE GLASSES
OF WATER. GET IMMEDIATE MED ATTN.

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DO NOT EXPOSE AEROSOLS TO TEMPERATURES
ABOVE 130F OR THE CONTAINER MAY RUPTURE. THERMAL DECOMPOSITION
PRODUCTS MAY INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:ABSORB WITH SUITABLE MEDIUM. INCINERATE OR
LANDFILL ACCORDING TO LOCAL, STATE OF FEDERAL REGULATIONS. ALLOW TO
EVAPORATE IF SMALL SPILL. DO NOT FLUSH TO SEWER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT PUNCUTRE/INCIN CNTNRS. DO NOT
STORE AT TEMPS ABOVE 130F. KEEP OUT OF REACH OF CHILDREN. AVOID
FOOD CONTAMINATION. AVOID INHALATION OF VAPORS.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICINITY
OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIA MAY
CAUSE FORMATION OF HCL &/OR PHOSGENE .

Exposure Controls

Respiratory Protection:IF VAPOR CONCENTRATION EXCEEDS TLV, USE
NIOSH/MSHA APPROVED BY U.S. BUREAU OF MINES FOR ORGANIC VAPOR.
Ventilation:ADEQUATE VENTILATION TO KEEP VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:WASH WITH SOAP AND WATER BEFORE HANDLING FOOD.
REMOVE CONTAMINATED CLOTHING.
Supplemental Safety and Health
SPEC GRAV (H*2O=1):CONCENTRATE ONLY = 1.60. VP:PSIG @
70F(AEROSOLS):85-100. EVAP RATE (N-BUTYL ACETATE =1): 2.1
(CONCENTRATE ONLY). EXPLAN OF CARCIN:PERCHLOROETHYLENE:IARC MONO ON
EVAL OF CARCIN RISK OF CHEMS TO MAN, VOL 63, PG 159, 1995:GROUP
2A. NTP 7TH ANNUAL RPT ON CARCINS, 1994:ANTIC TO BE CARCINOGEN.

Chemical Properties

Vapor Pres:SUPDAT
Spec Gravity:SUPDAT
Evaporation Rate & Reference:SUPP DATA
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR, COLORLESS SPRAY WITH CHLORINATED SOLVENT
ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
REACTIVE METALS, ALUMINUM, MAGNESIUM, STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAME, WELDING ARCS, HEAT.
Hazardous Decomposition Products:CO*2, CO, HCL, SMALL AMOUNTS OF
PHOSGENES AND CHLORINE.

Disposal

Waste Disposal Methods:AEROSOL CANS WHEN VENTED TO ATMOSPHERIC PRESSURE
THROUGH NORMAL USE, POSE NO DISPOSAL HAZARD. DISPOSAL MUST BE IN
ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.